.jpg)
| Item | Value |
|---|---|
| Measured gases | VOCs can volatilize gases |
| Measuring range | 0~1000ppm/0.1~2000ppm |
| Detection principle | |
| Accuracy | |
| Resolution | 1ppm/0.1ppm |
| Response time | < 15 seconds |
| Ingress protection | IP54 |
| Explosion protection | |
| Operating temperature | -20℃ ~+55℃ |
| Power supply | Built-in rechargeable lithium battery, 3.7V, 1800mAh |
| Output signal |
ToxiRAE Pro PID personal VOC detector can perform fast, reliable and accurate detection of various VOCs under different temperature and humidity conditions, suitable for hazardous working environments with toxic / flammable gas, and can provide effective personal safety protection for field workers.

ToxiRAE Pro PID Personal VOC Detector Probe PGM-1800 Reference Diagram


ToxiRAE Pro PID Personal VOC Detector Probe PGM-1800 Details Parameters
|
Product Type:
|
Diffusion PID detector with data storage and auxiliary fan
|
|
Detect Measuring range
|
0~1000ppm/0.1~2000ppm
|
|
Resolution
|
1ppm/0.1ppm
|
|
Response time T90
|
< 15 seconds
|
|
Size:
|
118 mm×60 mm×30 mm
|
|
weight
|
235g
|
|
battery
|
Built-in rechargeable lithium battery, 3.7V, 1800mAh
|
|
Charging time
|
Less than 4 hours
|
|
Working hours
|
A full charge is greater than 12 hours
|
|
charger
|
Single charger with USB port / Five-instrument charger without USB port
|
|
Alarm style
|
Sound alarm 95 dB@30cm, red LED alarm light, vibration alarm
|
|
shown
|
Monochrome LCD graphic display
|
|
Backlight
|
Manual, automatic when alarmed
|
|
Keyboard
|
2 keys
|
|
Direct reading
|
Measured values, battery, data logging status
|
|
Sampling method
|
Diffusion with auxiliary fan
|
|
Data logging
|
The 1-minute interval can be stored for 3 months, and the recording interval is 1~3600 seconds
|
|
calibration
|
Two-point calibration, calibration value can be set
|
|
Ingress protection
|
IP54
|
|
calibration equipment
|
Supports AutoRAE Lite 2 automatic calibration platform
|
|
Protection
|
Calibration, alarm and other limits are password protected
|
|
Wireless transmission distance
|
100 meters
|
|
Certification
|
UL / CSA:Class I, Division 1 Groups A, B, C, D
ATEX:II 1G Ex ia IIC T4
IECEx:ia IIC Ga T4
Chinese explosion-proof: Ex ia IIC T4
|
|
Electromagnetic compatibility
|
EMC Directive 2004/108/EC
R&TTE Directive 1999/5/EC ATEX: 94/9/EC
|
|
Performance testing protocols
|
US and Canada: CSA152
Europe: IEC60079-29(EN61779-1,-4)
China: GB12358(CMC)
|
|
Operating temperature
|
-20℃ ~+55℃
|
|
Humidity
|
0~95% relative humidity (non-condensing)
|
|
Warranty
|
One year warranty
|