| Item | Value |
|---|---|
| Measured gases | VOCs can volatilize gases |
| Measuring range | |
| Detection principle | photoionization |
| Accuracy | ±3%F.S. |
| Resolution | |
| Response time | 15s |
| Ingress protection | IP66 |
| Explosion protection | |
| Operating temperature | -40℃~+55℃ |
| Power supply | 12~30VDC |
| Output signal |
The RAEGuard PID is a flameproof, fixed-mount organic gas detector. It can be widely used in petroleum, petrochemical, metallurgy, chemical industry, environmental protection, papermaking, printing and dyeing, municipal, scientific research, education, national defense and other fields.

RAEGuard PID organic gas detector probe FGM-100X sound and light alarm product diagram
PID technology development
It adopts RAE's self-developed PID sensor
Self-cleaning technology
The use of automatic cleaning technology ensures the long-term stable operation of the fixed instrument and extends the service life of the sensor
Exclusive pump sampling
It adopts a built-in powerful sampling pump, which has a large monitoring range and shorter response and recovery time
Thousands of gases can be detected
Broad-spectrum detection for quantitative detection of unknown gases
Multiple signal outputs
Standard 4-20mA (three-wire), two-stage alarm relay output
User-friendly interface
Intuitive, clear large-character LCD display and local alarm indication
No need to open the lid, magnetic stick operation
Integrated sound and light alarm (optional)
High temperature and humidity resistance
The temperature and humidity compensation algorithm is adopted, which can be applied to extremely harsh working conditions
Excellent quality
It has been widely used in many enterprises and has successfully provided users with security support and guarantee for more than 10 years
Certification
Passed ATEX, UL and other certifications
|
Detection principle
|
photoionization
|
|
Sampling method
|
Pump suction type
|
|
Power supply
|
12~30VDC
|
|
Power
|
125mA@24VDC
|
|
Output signal
|
4~20mA
|
|
Load impedance
|
600Ω
|
|
Other outputs
|
Two-stage passive relay 30VDC 2A
|
|
Accuracy
|
±3%F.S.
|
|
Response time(T90)
|
15s
|
|
Electrical interface
|
3/4” NPT M
|
|
Installation method:
|
2" riser/wall mount
|
|
Ingress protection
|
IP66
|
|
Ambient temperature
|
-40℃~+55℃
|
|
Ambient humidity
|
0~95% RH (no condensation)
|
|
Environmental stress
|
86kPa~106kPa
|
|
Display:
|
LCD display, four-color alarm indicator
|
|
Dimensions
|
138mm×151mm×118mm(HWD)
|
|
Shell material
|
Aluminum alloy
|
|
weight
|
2.5kg
|
|
ATEX
|
(EX)II G EEx d II BT6
|
|
UL
|
Class I, Division 1, Groups B, C and D
|
|
Explosion-proof certification
|
Ex d II CT6
|
Configuration information
|
Standard configuration
|
Detector host, operation manual, standard gas cover, installation accessories
|
|
Optional configuration
|
Sound and light alarms, standard gas, pressure reducing valves, etc
|
It is used in petroleum, petrochemical, metallurgy, chemical industry, environmental protection, papermaking, printing and dyeing, municipal, scientific research, education, national defense and other fields.