| Item | Value |
|---|---|
| Measured gases | COcarbon monoxide、O2oxygen、H2Shydrogen sulfide |
| Measuring range | Different gases have different Measuring ranges |
| Detection principle | electrochemical |
| Accuracy | ±2%F.S. |
| Resolution | |
| Response time | <15s |
| Ingress protection | IP65 |
| Explosion protection | |
| Operating temperature | -40℃ ~+60℃ |
| Power supply | 9~36VDC |
| Output signal |
RAEGuardS EC is a new generation of toxic gas detector launched on the basis of RAEGuard EC's ten years of industry application, is a flameproof gas detector using intelligent digital electrochemical sensor detection technology, fixed installation method, FGM-1300S can detect a variety of toxic gases such as oxygen, CO, H2S, etc. In terms of external functions, the FGM-1300Sgas detector probe adopts LCD display and LED status display, which can display the concentration of measured gases and the working status of the detector on the spot.

RAEGuard ECToxic gas detectors probe FGM-1300S

Detailed explanation of FGM-1300SToxic gas detectors probe
FGM-1300SToxic gas detectorsoxygenhydrogen sulfide alarm electronic data download
|
Detection principle
|
electrochemical
|
|
sensors
|
Smart sensors
|
|
Sampling method
|
Diffusion
|
|
Power supply
|
9~36VDC
|
|
Power
|
40mA@24VDC
|
|
Output signal
|
4~20mA, can be fine-tuned
|
|
Load impedance
|
600Ω
|
|
Other outputs
|
RS485 Modbus, two-stage programmable passive relay 30VDC 2A
|
|
Accuracy
|
±2%F.S.
|
|
Response time (T90)
|
<15s
|
|
Electrical interface
|
3/4” NPT M
|
|
Installation method:
|
2" riser / wall mount
|
|
Display:
|
LCD display, four-color alarm indicator
|
|
Ingress protection
|
IP65
|
|
Ambient temperature
|
-40℃ ~+60℃
|
|
Ambient humidity
|
0~95% RH (no condensation)
|
|
Environmental stress
|
86kPa ~106kPa
|
|
Dimensions
|
188mm×150mm×109mm(HWD)
|
|
Shell material
|
Stainless steel
|
|
weight
|
3.5kg
|
|
ATEX
|
(Ex)II 2G EEx d Ⅱ CT6
|
|
UL/CSA
|
Class I, Div. 1&2, Groups BCD T6
|
|
IECEx
|
Ex d II CT6
|
|
Explosion-proof certification
|
Ex d II CT6
|
|
Product model
|
Detect gases
|
Standard Measuring range
|
Resolution
|
Order number
|
|
FGM-1300S
|
CO
|
0 ~ 1000ppm
|
1ppm
|
036-0805-C20
|
|
FGM-1300S
|
CO
|
Measuring range can be set within 200 ~ 1000
|
036-0805-C21
|
|
|
FGM-1300S
|
H2S
|
0 ~ 300ppm
|
1ppm
|
036-0805-C10
|
|
FGM-1300S
|
H2S
|
Measuring range can be set within 30 ~ 300
|
036-0805-C11
|
|
|
FGM-1300S
|
O2
|
0 ~ 30%VOL
|
0.1%VOL
|
036-0805-C70
|