| Item | Value |
|---|---|
| Measured gases | NH3ammonia |
| Measuring range | |
| Detection principle | electrochemical |
| Accuracy | |
| Resolution | |
| Response time | |
| Ingress protection | IP65 |
| Explosion protection | |
| Operating temperature | -30~50℃ |
| Power supply | |
| Output signal |
There is no detailed description of this product, and the basic parameter information has been retained.
Compact form factor and rugged durability
The operating time is adjustable and easy to use
Sound, light and vibration alarms, large screen display
Data logger
New sensor technology
Type: flameproof gas transmitter
gas and Measuring range: toxic gas: 20/50/100ppm ; H2S:100/300/500ppm ; CO:25% vol. O2
Display: 3-digit LCD display; Display Resolution is based on Measuring range (see the corresponding sensor specification table)
Output signal: Analog: 4~20mA
Maintenance signal: 4mA+/-1mA, 1Hz modulation; or constant 3mA (user optional)
Fault Signal: <2mA
Operating Voltage: 16 ~30VDC (usually 24VDC)
Environmental conditions: Temperature: 40~+65°C
Air pressure: 700~1300 mbar
Humidity: 5~95% r.h.
(See sensor data sheet)
Housing: Cast aluminum transmitter housing, stainless steel sensor guard
Ingress protection:NEMA 4X, IP65
Dimensions & Weight: 235×114×102mm (H×W×D)
2.5kg
Certification: UL: Class I, Div I, Group B, C, D
CENELEC: EEx d II B T5
It is suitable for industrial safety monitoring and on-site inspection scenarios.